    Abstract:

    AIM: To compare the anterior chamber volume and corneal volume using Pentacam in people with early keratoconus, subclinical keratoconus, and healthy subjects.

    METHODS: This epidemiologic study was performed on 63 patients who were candidates for refractive surgery. We classified our patients into three groups as normal, subclinical keratoconus, and early keratoconus according to the Amsler-Krumeich criteria. We collected demographic information, including age and sex, and obtained a full medical history of the patients. Complete visual examination was performed for all patients. Then, using Pentacam, corneal volume and anterior chamber volume were measured among three groups.

    RESULTS: Corneal volume in the control group was significantly higher than the subclinical keratoconus and early keratoconus groups(P<0.05), but the anterior chamber volume was not significantly different between the groups(P>0.05).

    CONCLUSION: Measuring the corneal volume can help to distinguish the eyes with subclinical keratoconus and early keratoconus from normal eyes. The chamber volume might not differ remarkably among people with subclinical keratoconus, early keratoconus, and those with normal eyes.

    Reference
    Related
    Cited by
Get Citation

Ostadian F, Farrahi F, Mahdian Rad A, Mirdehghan MS. 使用Pentacam检测亚临床期和早期圆锥角膜患者角膜体积和前房容积. 国际眼科杂志2020;20(5):745-748,DOI:10.3980/j. issn.1672-5123.2020.5.01

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
Publication History
  • Received:August 01,2019
  • Revised:March 11,2020
  • Adopted:
  • Online: April 26,2020
  • Published: