Risk factors of secondary intraocular hypertension after silicone oil tamponade
Author:
  • Article
  • | |
  • Metrics
  • |
  • Reference [38]
  • |
  • Related [20]
  • | | |
  • Comments
    Abstract:

    Silicone oil, as a temporary vitreous substitute, has been widely applied to the treatment of various complex vitreoretinal disease. However, silicone oil tamponade also causes a variety of postoperative complications, the most common of which is temporary or permanent elevated intraocular pressure(IOP). A number of studies have shown that intraocular pressure after silicone oil filling is affected by a variety of factors. In this paper, the progress on the risk factors and pathogenesis of secondary high intraocular pressure after silicone oil tamponade are reviewed, which might provide a reference for the timely and effective control of IOP.

    Reference
    1 Teke MY,Elgin U,Sen E, et al. Intravitreal silicone oil induced changes in corneal biomechanics. Int Ophthalmol 2014; 34(3):1-7
    2 Russo A, Morescalchi F, Donati S,et al.Heavy and standard silicone oil:intraocular inflammation. Int Ophthalmol 2018; 38(2):855-867
    3 Pastor JC. Proliferative vitreoretinopathy: an overview. Surv Ophthalmol 1998; 43(1):3-18
    4 Azen SP, Scott IU, Flynn HW,et al. Silicone oil in the repair of complex retinal detachments. A prospective observational multicenter study. Ophthalmology 1998; 105(9):1587-1597
    5 Nadal J, Verdaguer P, Canut MI. Treatment of retinal detachment secondary to macular hole in high myopia:vitrectomy with dissection of the inner limiting membrane to the edge of the staphyloma and long-term tamponade. Retina 2012; 32(8):1525-1530
    6 Wei Y, Li Y, Chen F. Vitrectomy treatment of retinal detachments related to choroidal coloboma involving the disk. Retina 2014; 34(6):1091-1095
    7 Fang Y,Long Q,Wang X,et al. Intraocular pressure 1 year after vitrectomy in eyes without a history of glaucoma or ocular hypertension. Clin Ophthalmol 2017; 11:2091-2097
    8 Parke DW 3rd, Sisk RA,Houston SK,et al. Ocular hypertension after intravitreal triamcinolone with vitrectomy and phacoemulsifcation. Clin Ophthalmol 2012; 6:925-931
    9 Jonas JB, Knorr HL, Rank RM,et al. Intraocular pressure and silicone oil endotamponade. J Glaucoma 2001; 10(2):102-108
    10 Jabbour E,Azar G,Antoun J,et al. Incidence and risk factors of ocular hypertension following pars plana vitrectomy and silicone oil injection. Ophthalmologica 2018\〖Epub ahead of print\〗
    11 Liu Z,Fu G,Liu A, et al. The relationship between inflammatory mediator expression in the aqueous humor and secondary glaucoma incidence after silicone oil tamponade. Exp Ther Med 2017; 14(6):5833-5836
    12 Rosca C, Munteanu M, Tamasoi I,et al. Calcification of hydrophilic acrylic intraocular lens in eyes with silicone oil tamponade-an interventional case series report. Acta Ophthalmol 2016; 94(6):625-627
    13 Nguyen QH, Llyod MA, Huer DK,et al. Incidence and management of glaucoma after intravitreal silicone oil injection for complicated retinal detachments. Ophthalmology 1992; 99(10):1520-1526
    14 Kornmann HL,Gedde SJ. Glaucoma management after vitreoretinal surgeries. Curr Opin Ophthalmol 2016; 27(2):125-131
    15 Francis JH, Latkany PA, Rosenthal JL. Mechanical energy from intraocular instruments cause emulsification of silicone oil. Br J Ophthalmol 2007; 91(6):818-821
    16 Barca F, Caporossi T, Rizzo S. Silicone Oil: different physical proprieties and clinical applications. Biomed Res Int 2014; 2014:502143
    17 Han DP, Lewis H, Lambrou FH Jr, et al. Mechanisms of intraocular pressure elevation after pars plana vitrectomy. Ophthalmology 1989; 96(9):1357-1362
    18 Miller JB, Papakostas TD, Vavvas DG. Complications of emulsified silicone oil after retinal detachment repair. Semin Ophthalmol 2014; 29(5-6):312-318
    19 Stappler T, Morphis G, Irigoyen C, et al. Is there a role for long-term silicone oil tamponade for more than twelve months in vitreoretinal surgery? Ophthalmologica 2011; 226(suppl 1):36-41
    20 Romano V, Cruciani M,Semeraro F,et al. Development of ocular hypertension secondary to tamponade with light versus heavy silicone oil: A systematic review. Indian J Ophthalmol 2015; 63(3):227-232
    21 Ohira A,Wilson CA,deJuan E Jr,et al. Experimental retinal tolerance to emulsified silicone oil. Retina 1991; 11(2):259-265
    22 Ichhpujani P, Jindal A, Jay Katz L. Silicone oil induced glaucoma: A review. Graefes Arch Clin Exp Ophthalmol 2009; 247(12):1585-1593
    23 Moisseiev J, Barak A, Manaim T, et al. Removal of silicone oil in the management of glaucoma in eyes with emulsified silicone. Retina 1993; 13(4):290-295
    24 Shin J,Jeon H,Byon IS,et al. Goniosynechiaiysis for secondary angle closure glaucoma in a pseudophakic patient after vitrectomy and silicone oil injection. Int J Ophthalmol 2014; 7(5):914-916
    25 Sahoo NK, Balijepalli P,Singh SR,et al. Retina and glaucoma:surgical complications. Int J Retina Vitreous 2018; 4:29
    26 Crisp A, de Juan E Jr, Tiedeman J. Effect of silicone oil viscosity on emulsification. Arch Ophthalmol 1987; 105(4):546-550
    27 Muether PS, Hoerster R, Kirchhof B, et al. Course of intraocular pressure after vitreoretinal surgery: is early postoperative intraocular pressure elevation predictable? Retina 2011;(8):1545-1552
    28刘晓丹,李秋明.糖尿病患者硅油注入术后早期高眼压的因素分析.河南医学研究2012; 21(4):421-423
    29 Honavar SG, Goyal M, Majji AB, et al. Glaucoma after pars plana vitrectomy and silicone oil injection for complicated retinal detachments. Ophthalmology 1999; 106(1):169-176
    30 Yazici A,Sen E,Ozdal P,et al. Factors affecting intraocular pressure measured by noncontact tonometer. Eur J Ophthalmol 2009; 19(1):61-65
    31 Wu L,Berrocal MH,Rodriguez FJ, et al. Intraocular pressure elevation after uncomplicated pars plana vitrectomy. Retina 2014; 34(10):1985-1989
    32 Jackson TL,Thiagarajan M,Murthy R,et al.Pupil block glaucoma in phakic and pseudophakic patients after vitrectomy with silicone oil injection. Am J Ophthalmol 2001; 132(3):414-416
    33 Jurišic ' D, Geber MZ, C'avar I,et al. Retinal layers measurements following silicone oil tamponade for retinal detachment surgery. Semin Ophthalmol 2018; 33(5):711-718
    34 Shin J,Lee JW,Kim EA, et al. The effect of corneal biomechanical properties on rebound tonometer in patients with normal-tension glaucoma. Am J Ophthalmol 2015; 159(1):144-154
    35 Mansouri K,Leite MT,Weinreb RN, et al. Association between Corneal Biomechanical Properties and Glaucoma Severity. Am J Ophthalmol 2012; 153(3):419-427
    36 Teke MY,Elgin U,Sen E,et al. Intravitreal silicone oil induced changes in corneal biomechanics. Int Ophthalmol 2014; 34(3):457-463
    37 Xu L,Wang Y,Wang S,et al. High myopia and glaucoma susceptibility. Ophthalmology 2007; 114(2):216-220
    38 Burk LL, Shields MB, Proia AD,et al. Intraocular pressure following intravitreal silicone oil injection. Ophthalmic Surg 1988; 19(8):565-569
    Cited by
    Comments
    Comments
    分享到微博
    Submit
Get Citation

De-Ju Kong, Xu-Hui Yu. ,/et al.Risk factors of secondary intraocular hypertension after silicone oil tamponade. Guoji Yanke Zazhi( Int Eye Sci) 2018;18(11):2003-2006

Copy
Share
Article Metrics
  • Abstract:1102
  • PDF: 1175
  • HTML: 0
  • Cited by: 0
Publication History
  • Received:June 26,2018
  • Revised:September 20,2018
  • Online: October 22,2018