Analysis of angle Kappa variation in corneal refractive surgery under light and dark conditions
Author:
Corresponding Author:

Affiliation:

Clc Number:

Fund Project:

Science and Technology Developing Project of the Fourth Military Medical University 2016(No.2016XC209)

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    AIM: To observe the values and changing rules of angle Kappa in corneal refractive surgery under light and dark conditions.

    METHODS:Two hundred and thirty-four eyes of 118 patients for corneal refractive surgery were enrolled for this study. Pupil diameters and angle Kappa values under light and dark conditions were measured by Keratron Scout corneal topography.

    RESULTS: There were significant differences in pupil diameters between light and dark conditions(P<0.01). More angle Kappa of both eyes distributed in the superior nasal quadrant under light conditions, and more angle Kappa distributed in the superior temporal quadrant under dark conditions. The differences of horizontal and vertical offsets of angle Kappa under two conditions were statistically significant(P<0.01).

    CONCLUSION: The changes of pupil diameters in light and dark conditions could affect angle Kappa and then affect the accuracy of corneal refractive surgery centered on angle Kappa.

    Reference
    Related
    Cited by
Get Citation

Rong Shi, Ze-Hong Dong, Wei Zhao, et al. Analysis of angle Kappa variation in corneal refractive surgery under light and dark conditions. Guoji Yanke Zazhi( Int Eye Sci) 2016;16(8):1462-1464

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
Publication History
  • Received:April 22,2016
  • Revised:July 07,2016
  • Adopted:
  • Online: July 26,2016
  • Published: