Subfoveal choroidal thickness measured by Cirrus HD optical coherence tomography in myopia
Author:
Corresponding Author:

Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    ATM: To measure the subfoveal choroidal thickness(SFCT)in myopia using Cirrus HD optical coherence tomography(OCT), and to explore the relationship between the SFCT, axial length and myopic refractive spherical equivalent.

    METHODS: One-hundred thirty-three eyes of 70 healthy volunteers were recruited, and were divided into emmetropia group, low-degree myopia, middle-degree myopia and high-degree myopia group. SFCT were measured by Cirrus HD OCT, and the relationship between the SFCT, axial length and myopic refractive spherical equivalent were evaluated.

    RESULTS: 1)Average SFCT was(275.91±55.74)μm in normals, that in emmetropia group, low-degree myopia, middle-degree myopia and high-degree myopia group were(290.03±34.82)μm,(287.64±51.51)μm,(274.95±56.83)μm,(248.37±67.98)μm; 2)the SFCT of high-degree myopia group was significant thinner than that of emmetropia group(P<0.05); 3)There was a significant negatives correlation between the SFCT and axial length(P<0.01), a significant positive correlation between SFCT and myopic refractive spherical equivalent(P<0.01).

    CONCLUSION: the SFCT is inversely correlated with increasing axial length and myopic refractive error.

    Reference
    Related
    Cited by
Get Citation

Li-Li Chen, Zi-Lin Chen, Ze-Bin Li. Subfoveal choroidal thickness measured by Cirrus HD optical coherence tomography in myopia. Guoji Yanke Zazhi( Int Eye Sci) 2014;14(9):1641-1643

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
Publication History
  • Received:March 11,2014
  • Revised:August 05,2014
  • Adopted:
  • Online: August 19,2014
  • Published: