Latest research progress of adjustable intraocular lens
Author:
Fund Project:

Key Science and Technology Project of Liaoning Province(No. 2012225012)

  • Article
  • | |
  • Metrics
  • |
  • Reference [20]
  • |
  • Related [20]
  • | | |
  • Comments
    Abstract:

    Despite the many advances in cataract surgery, incorrect intraocular lens(IOL)power remains a significant clinical problem which seriously affects the postoperative visual quality and satisfaction. Adjustable intraocular lens can be adjusted to provide a new way to solve this problem. The general concepts and clinical significances of adjustable IOL, as well as the designs and studies of several kinds of adjustable IOL, are described in this review. Adjustable IOL will give a new technological innovation to the cataract surgery to improve outcomes and increase expectations.

    Reference
    1 Ford J,Werner L,Mamalis N. Adjustable intraocular lens power technology. J Cataract Refract Surg 2014; 40(7):1205-1223
    2 Jin GJC,Crandall AS,Jones JJ. Intraocular lens exchange due to incorrect lens power. Ophthalmology 2007; 114(3):417-424
    3滕贺,张红. 人工晶状体置换术的临床观察. 中国实用眼科杂志2012; 30(7):840-843
    4赵姝芝,蔡可丽. 儿童白内障手术人工晶状体度数计算准确性分析. 中国实用眼科杂志 2011; 29(8):847-849
    5 Werblin TP. Multicomponent intraocular lens. J Cataract Refract Surg 1996; 12(1):187-189
    6 Partaliou DM,Grentzelos MA,Pallikaris IG. Multicomponent intraocular lens implantation:two-year follow-up. J Cataract Refract Surg 2013; 39(4):578-584
    7 Jahn CE,Jahn MA,Kreiner CF,et al. Intraocular lens with reversibly adjustable optic power; pilot study of concept and safety. J Cataract Refract Surg 2003; 29(9):1795-1799
    8 Jahn CE,Strotmann H. Investigation of the safety of an intraocular lens with adjustable optical power:the Acri. Tec AR-1PC/IOL. Ophthalmologica 2005; 219(6):362-365
    9 Jahn CE,Schöpfer DC. Cataract surgery with implantation of a mechanically and reversibly adjustable intraocular lens:*Acri.Tec AR-1 posterior chamber intraocular lens. Arch Ophthalmol 2007; 125(7):936-939
    10 Matthews MW,Eggleston HC,Pekarek SD,et al. Magnetically adjustable intraocular lens. J Cataract Refract Surg 2003; 29(11):2211-2216
    11 Simonov AN,Vdovin G,Loktev M. Liquid-crystal intraocular adjustable lens with wireless control. Opt Express 2007; 15(12):7468-7478
    12 Ding L,Knox WH,Bühren J,et al. Intratissue refractive index shaping(IRIS)of the cornea and lens using a low-pulse-energy femtosecond laser oscillator. Invest Ophthalmol Vis Sci 2008; 49(12):5332-5339
    13 Träger J,Heinzer J,Kim HC,et al. Polymers for in vivo tuning of refractive properties in intraocular lenses. Macromol Biosci 2008; 8(2):177-183
    14张振平. 人工晶状体屈光手术学. 北京:人民卫生出版社2009:9
    15 Werner L,Chang W,Haymore J,et al. Retinal safety of the irradiation delivered to light-adjustable intraocular lenses evaluated in a rabbit model. J Cataract Refract Surg 2010; 36(8):1392-1397
    16 Hengerer FH,Dick HB,Buchwald S,et al. Evaluation of corneal endothelial cell loss and corneal thickness after cataract removal with light-adjustable intraocular lens implantation:12-month follow-up. J Cataract Refract Surg 2011; 37(12):2095-2100
    17 Chayet S,Sandstedt C,Chang S,et al. Correction of myopia after cataract surgery with a light-adjustable lens. Ophthalmology 2009; 116(8):1432-1435
    18 Chayet S,Sandstedt C,Chang S,et al. Correction of residual hyperopia after cataract surgery using the light adjustable intraocular lens technology. Am J Ophthalmol 2009; 147(3):392-397
    19 von Mohrenfels CW,Salgado J,Khoramnia R,et al. Clinical results with the light adjustable intraocular lens after cataract surgery. J Cataract Refract Surg 2010; 26(5):314-320
    20 Hengerer FH,Hütz WW,Dick HB,et al. Combined correction of axial hyperopia and astigmatism using the light adjustable intraocular lens. Ophthalmology 2011; 118(7):1236-1241
    Cited by
    Comments
    Comments
    分享到微博
    Submit
Get Citation

Jing Wang, Lu Lu, Jiang-Yue Zhao,/et al.Latest research progress of adjustable intraocular lens. Guoji Yanke Zazhi( Int Eye Sci) 2016;16(3):455-457

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
Publication History
  • Received:November 12,2015
  • Revised:February 14,2016
  • Online: March 02,2016