Comparison of visual quality between LASIK flap made by femtosecond laser and by microkeratome
Author:
  • Article
  • | |
  • Metrics
  • |
  • Reference [11]
  • |
  • Related [20]
  • |
  • Cited by
  • | |
  • Comments
    Abstract:

    AIM: To compare the visual quality of LASIK flap made by femtosecond laser with that by microkeratome.

    METHODS: Retrospective case series research was undertaken. In 2011, there were 150 cases(300 eyes)underwent LASIK surgery from June to September. The patients were divided into 2 groups: flap made by femtosecond laser was group 1; flap made by microkeratome was group 2, with 75 cases(150 eyes)for each group. All surgeries performed stroma ablation with EC5000CX-Ⅱ(NIDEK CO., LTD)by the same surgeon. Uncorrected visual acuity(UCVA), diopter before operation and one week, one month, three months after the operation were compared between two groups, as well as corresponding data of the best corrected visual acuity, wavefront aberrations, the scotopic and photopic contrast sensitivity.

    RESULTS: The refractive diopter and uncorrected visual acuity between 2 groups had no significant difference at 1 week,1 month and 3 months after operation. Absolute value of C7, RMS3, RMS6 and RMSh of femtosecond laser group were lower compared with microkeratome group at 1 month after operation(P<0.05). C7 and C14 of femtosecond laser group were also lower at 3 months after operation(P<0.05). At 1 week after operation, the photopic and mesopic contrast sensitivity function in two groups decreased for all spatial frequencies, there were statistical differences compared with which before operation(P<0.05). The scotopic and photopic contrast sensitivity of the first postoperative month was increased compared with that of the first postoperative week. Till the third postoperative month, the contrast sensitivity function in two groups restored to preoperative level. The difference showed no statistic significance.

    CONCLUSION: LASIK flap made by femtosecond laser can safely and effectively correct myopia and astigmatism. Femtosecond can improve UCVA and visual quality, decrease high order aberration without reducing postoperative contrast sensitivity. Its postoperative outcome is much better than that of LASIK flap made by microkeratome.

    Reference
    1 Pietil J,Huhtala A,Jskelinen M,et al. LASIK flap creation with the Ziemer femtosecond laser in 787 consecutive eyes. J Refract Surg 2010; 26(1):7-16
    2于志强,许烨,姚佩君,等. 准分子激光手术不同制瓣方式角膜瓣厚度的研究. 中华眼科杂志2010; 46(3):203-208
    3 Burkhard von J,Thomas K. Corneal architecture of femtosecond laser and microkeratome flaps imaged by anterior segment optical coherence tomography. J Cataract Refract Surg 2009; 35(1):35-41
    4 Vryghem JC,Devogelaere T,Stodulka P. Efficacy,safety,and flap dimensions of a new femtosecond laser for laser in situ keratomileusis. J Cataract Refract Surg 2010; 36(3):442-448
    5 Lee PJ,Liu CJ,Wojciechowski R,et al.Structure-function correlations using scanning laser polarim-etry in primary angle-closure glaucoma and primary open angle glaucoma. Am J Ophthalmol 2010; 149(5):817-825
    6 Kezirian GM,Stonecipher KG.Comparison of the IntraLase femtcsecond laser and mechanical keratomes for laser in situ keratomileusis. J Cataract Refract Surg 2004; 30(4):804-811
    7 Durrie DS,Kezifian GM.Femtosecond laser versus mechanical keratome flaps in wavefront-guided laser in situ keratomileusis:prospective contralateral eye study. J Cataract Refract Surg 2005; 31(1):120-126
    8 Tran DB,Sarayba MA,Bor Z, et al.Randomized prospective clinical study comparing induced aberrations with IntraLase and Hansatome flap creation in fellow eyes:potential impact on wavefront-guided laser in situ keratomileusis. J Cataract Refract Surg 2005; 31(1):97-105
    9 Kermani O,Oberheide U. Comparative micromorphologic in vitro porcine study of IntraLase and Femto LDV femtosecond lasers. J Cataract Refract Surg 2008; 34(8):1393-1399
    10王铮,邱平,杨斌.近视眼LASIK术后早期对比敏感度变化和眩光测试.中山大学学报2004; 25(5):489-492
    11 Montés-Micó R, Rodrìguez-Galietero A, Alió JL. Femtosecond lasik versus mechanical keratome LAS IK for myopia. Ophthalmology 2007; 114(1):62-68
    Cited by
    Comments
    Comments
    分享到微博
    Submit
Get Citation

Mu-Zhi Yuan, Ying Lin, Xia Zhang. ,/et al.Comparison of visual quality between LASIK flap made by femtosecond laser and by microkeratome. Guoji Yanke Zazhi( Int Eye Sci) 2013;13(11):2205-2208

Copy
Share
Article Metrics
  • Abstract:1634
  • PDF: 1267
  • HTML: 0
  • Cited by: 0
Publication History
  • Received:July 30,2013
  • Revised:October 15,2013
  • Online: October 28,2013