Clinical research on visual performance and pseudophakic accommodation of Tetraflex accommodative intraocular lens in cataract surgery
Author:
Corresponding Author:

Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    AIM: To obverse visual acuity, pseudophakic accommodation, visual performance after implantation of the Tetraflex accommodative intraocular lens(IOL)in patients with age-related cataract.

    METHODS: Case -control study. Forty-eight patients(seventy-two eyes)with age-related cataract received phacoemulsification and implantation of artificial intraocular lens in our department during March 2010 to December 2012. The patients were randomly divided into 2 groups: Tetraflex group( 23 cases 35 eyes)and SA60AT group(25 cases 37 eyes). All patients were assessed for visual acuity, accommodation amplitude and contrast sensitivity visual acuity in 1, 3 and 6mo after the surgery. The indexes were analyzed by SPSS 13.0 statistics software.

    RESULTS: There were no statistically significant differences in uncorrected distance visual acuity(UCDVA)and best-corrected distance visual acuity(BCDVA)between the two groups(P>0.05); while there were statistically significant differences in uncorrected near visual acuity(UCNVA)and distance-corrected near vision acuity(DCNVA)(P<0.05). There was no significant difference of contrast sensitivity between the 2 groups(P>0.05). The Tetraflex group has best accommodative amplitude than the SA60AT group(P<0.05), and there was no significant difference of contrast sensitivity between the 2 groups(P>0.05). The Tetraflex group had higher rate of spectable independence than the SA60AT group(82.9% vs 16.2%)(P<0.05).

    CONCLUSION: Tetraflex provides an excellent distance and near visual acuity, good amplitude of accommodation and decrease the dependence of spectacle, and improve the visual performance. But its long-term effect remains to be observed.

    Reference
    Related
    Cited by
Get Citation

Jun-Yi Xie, Shi-Gang Yan, Hao-Quan Lu, et al. Clinical research on visual performance and pseudophakic accommodation of Tetraflex accommodative intraocular lens in cataract surgery. Guoji Yanke Zazhi( Int Eye Sci) 2013;13(7):1330-1333

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
Publication History
  • Received:March 29,2013
  • Revised:June 24,2013
  • Adopted:
  • Online: July 01,2013
  • Published: