Clinical application of 23-gauge transconjunctival vitrectomy sutureless system
Author:
Corresponding Author:

Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    AIM: To investigate the clinical application value of 23-gauge transconjunctival vitrectomy sutureless system(23G TSV).

    METHODS:Totally, 140 patients(140 eyes)with vitreous retinal diseases underwent 23G TSV. During one month of follow-up, the operation method, operation time, operation effect, visual acuity, intraocular pressure, corneal endothelium and operation complication were recorded.

    RESULTS:(1)The initial operation success rate was 100%, the recurrence rate in one month was 0.71%. There had no infectious endophthalmitis or persistent incision leakage and other complications during the follow-up period;(2)The operation time was 20-95 minutes, the average was 46 minutes;(3)The length of the hospitalized time was 3-39 days, the average was 7 days;(4)The visual acuity was improved in 91.43% patients, the best-corrected visual acuity was 0.7, and the differences between preoperative and postoperative visual acuity was significant(P<0.01);(5)intraocular pressure(IOP/mmHg): The rate of low intraocular pressure(<7)was 7.14% before operation, 5%, 0.71% and 0.71% at 1, 5 days and one month after surgery, respectively; The rate of high intraocular pressure(>21)was 4.29% before operation, 4.29%, 12.14% and 5% at 1, 5 days and one month after surgery, respectively. The differences between preoperative and postoperative was significant(P<0.05);(6)The corneal endothelial density(/mm2): The result of preoperatively corneal endothelial density was 2 735.49±319.28, and after a month the corneal endothelial density was 2 694.14±354.08, the difference had no significance(P>0.05).

    CONCLUSION: Because of the short operation time, rapidly postoperative recovery, less operation complications and the advantages of wide application range, 23G minimally invasive vitrectomy technique has certain clinical application prospect.

    Reference
    Related
    Cited by
Get Citation

Ni-Ni Deng, Bin Qin, Shi-Ru Ni. Clinical application of 23-gauge transconjunctival vitrectomy sutureless system. Guoji Yanke Zazhi( Int Eye Sci) 2013;13(3):586-588

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
Publication History
  • Received:November 13,2012
  • Revised:February 17,2013
  • Adopted:
  • Online:
  • Published: