Application of 23-Gauge vitrectomy system in high altitude area
Author:
  • Article
  • | |
  • Metrics
  • |
  • Reference [14]
  • |
  • Related [20]
  • | | |
  • Comments
    Abstract:

    To investigate the application of 23-Gauge (23G) vitrectomy system in high altitude area. METHODS:In the applying of 23G vitrectomy system, the vitrectomy had been done for 32 cases (32 eyes), including vitreous hemorrhage, macular hole, macular pucker, posterior dislocation of lens, retinal detachment, Tersonz syndrome, vitreous hemorrhage combining with retinal detachment. RESULTS:The operations were successful, without expanding sclera puncture.The postoperative syndrome mainly was low IOP. CONCLUSION:In 2000, the clinical using of 23G vitrectomy system without conjunctival suture was first reported. It is more efficient than 25G vitrectomy system, which can process the retina around like 20G and has the advantage of healing fast ,seamless, short operation time and less postoperative syndrome as 25G vitrectomy system. So it can be widely applied in the vitrectomy in high altitude area.

    Reference
    1 Machemer R, Buettner H, Norton EW, et al . Vitrectomy: a pars plana approach. Trans Am Acad Ophthalmol Otolaryngol 1971;75(4):813-820
    2 OMalley C,Heintz RM. Vitrectomy via the pars plana-a new instrument system. Trans Pac Coast Otoophthamlol Soc Annu Meet 1972;53(4):121-137
    3 Chen JC. Sutureless pars plana vitrectomy through self-sealing sclerotomies. Arch Ophthalmol 1996;114(10):1273-1275
    4 Kreiger AE. Wound complications in pars vitrectomy. Retina 1993;13(4):335-344
    5 Fujii GY, De Juan E, Humayn MS, et al . Initial experience using the transconjunctival sutureless vitrectomy sysytem for vitreo-retinal surgery.
    Ophthamlology 2002;109(10):1814-1820
    6 Kim MJ, Park KH,Hwang JM, et al . The safety and efficacy of transconjunctival sutureless 23-gauge vitrectomy. Korean J Ophthalmol 2007;21(4):201-207
    7 Fine HF,Iranmanesh R, Iturralde D, et al . Outcomes of 77 consecutive cases of 23-gauge transconjunctival vitrectomy surgery for posterior segment disease. Ophthalmology 2007;114(6):1197-1200
    8 Oliveira LB, Reis PA. Silicone oil tamponade in 23-gauge transconjunctival sutureless vitrectomy. Retina 2007;27(8):1054-1058
    9 Romano MR,Groenwald C, Das R, et al . Removal of Densiron-68 with a 23-gauge transconjunctival vitrectomy system. Eye(Lond) 2009;23(3):715-717
    10 Erakgun T, Egrilmez S. Surgical outcomes of transconjunctival sutureless 23-gauge vitrectomy with silicone oil injection. Indian J Ophthalmol 2009;57(2):105-109
    11 Nagpal M, Wartikar S, Nagpal K. Comparison of clinical outcomes and wound dynamics of sclerotomy ports of 20, 25, and 23 gauge vitrectomy. Retina 2009;29(2):225-231
    12 Shaikh S, Ho S, Richmond PP, et al . Untoward outcomes in 25-gauge versus 20-gauge vitreoretinal surgery. Retina 2007;27(8):1048-1053
    13 Kunmioto DY, Kaiser RS. Incidence of end ophthalmitis after 20-and 25-gauge vitrectomy. Ophthalmology 2007;114(12):2133-2137
    Cited by
    Comments
    Comments
    分享到微博
    Submit
Get Citation

Ling Li. Application of 23-Gauge vitrectomy system in high altitude area. Guoji Yanke Zazhi( Int Eye Sci) 2012;12(4):778-779

Copy
Share
Article Metrics
  • Abstract:1476
  • PDF: 1378
  • HTML: 0
  • Cited by: 0
Publication History
  • Received:September 14,2011
  • Revised:February 23,2012