Effect of short-term exposure to light emitting diode-derived blue light on the ocular surface
Author:
Corresponding Author:

Affiliation:

Clc Number:

Fund Project:

Jilin Provincial Natural Science Foundation Project(No.YDZJ202401111ZYTS)

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    AIM: To investigate the effects of short-term exposure to light emitting diode(LED)-derived blue light on the human ocular surface.

    METHODS: This was a prospective, non-randomized, comparative clinical study. Healthy adult volunteers visiting the Physical Examination Department of our hospital between February 2026 and May 2026 were enrolled in this study after completing ocular surface examinations. Ocular surface disease index(OSDI), tear secretion volume, non-invasive keratograph break-up time(NIBUT), and corneal sodium fluorescein staining were measured before and after close-range exposure to LED-derived blue light. The tear film concentrations of oxidative stress markers, hexanoyl-lysine(HEL)and 4-hydroxy-2-nonenal(4-HNE), were quantified by enzyme-linked immunosorbent assay(ELISA). All measurements were performed at baseline, and at 1 h and 4 h after blue light exposure via smartphone.

    RESULTS: Thirty healthy adult volunteers aged 21-35 y were enrolled(young and middle-aged people have the longest smartphone usage duration), with a mean age of 27.70±4.04 y and a male-to-female ratio of 1∶1.The OSDI scores at 4 h were significantly elevated compared with baseline and 1 h(all P<0.05). NIBUT at 4 h decreased significantly relative to baseline and 1 h(all P<0.05). HEL concentrations at 4 h were significantly higher than those at baseline and 1 h(all P<0.05). There were no significant differences in tear secretion volume, corneal fluorescein staining and 4-HNE levels across all time points(all P>0.05).

    CONCLUSION: While minimizing excessive tear evaporation caused by prolonged inter-blink intervals during gazing and the accommodative-convergence load associated with near work, close-range exposure to blue light emitted by LEDs from smartphones not only exacerbates subjective symptom but also destabilizes the tear film and elevates oxidative stress levels in tears. This may increase ocular surface oxidative stress, thereby contributing to potential risks of corneal oxidative damage, ocular surface inflammation, and dry eye.

    Reference
    Related
    Cited by
Get Citation

Jin Haiyan, Li Zhengri. Effect of short-term exposure to light emitting diode-derived blue light on the ocular surface. Guoji Yanke Zazhi( Int Eye Sci) 2026;26(12):2220-2223

Copy
Article Metrics
  • Abstract:
  • PDF:
Publication History
  • Received:July 15,2026
  • Revised:October 16,2026
  • Adopted:
  • Online: November 09,2026
  • Published: