    Abstract:

    AIM: To determine the teaching effects of a real-time three dimensional (3D) visualization system in the operating room for early-stage phacoemulsification training. METHODS: A total of 10 ophthalmology residents of the first-year postgraduate were included. All the residents were novices to cataract surgery. Real-time cataract surgical observations were performed using a custom-built 3D visualization system. The training lasted 4wk (32h) in all. A modified International Council of Ophthalmology’s Ophthalmology Surgical Competency Assessment Rubric (ICO-OSCAR) containing 4 specific steps of cataract surgery was applied. The self-assessment (self) and expert-assessment (expert) were performed through the microsurgical attempts in the wet lab for each participant. RESULTS: Compared with pre-training assessments (self 3.2±0.8, expert 2.5±0.6), the overall mean scores of post-training (self 5.2±0.4, expert 4.7±0.6) were significantly improved after real-time observation training of 3D visualization system (P<0.05). Scores of 4 surgical items were significantly improved both self and expert assessment after training (P<0.05). CONCLUSION: The 3D observation training provides novice ophthalmic residents with a better understanding of intraocular microsurgical techniques. It is a useful tool to improve teaching efficiency of surgical education.

    Reference
    Related
    Cited by
Get Citation

Zhe Xu, Dan Chen, Jing-Wei Xu, et al. Utility of real-time 3D visualization system in the early stage of phacoemulsification training. Int J Ophthalmol, 2024,17(3):577-582

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
Publication History
  • Received:April 22,2023
  • Revised:January 10,2024
  • Adopted:
  • Online: February 27,2024
  • Published: