Image-guided lens extraction surgery: a systematic review
Author:
Corresponding Author:

Eirini-Kanella Panagiotopoulou. Department of Ophthalmology, University Hospital of Alexandroupolis, Dragana, Alexandroupolis 68100, Greece. eipanagi@med.duth.gr

  • Article
  • | |
  • Metrics
  • |
  • Reference [65]
  • |
  • Related [20]
  • | | |
  • Comments
    Abstract:

    A systematic review of the recent literature regarding the current image-guided systems used for cataract surgery or refractive lens exchange was performed based on the PubMed and Google Scholar databases in March 2018. Literature review returned 21 eligible studies. These studies compared image-guided systems with other keratometric devices regarding their accuracy, repeatability and reproducibility in measurement of keratometric values, astigmatism magnitude and axis, as well as in IOL power calculation. Additionally, the image-guided systems were compared with conventional manual ink-marking techniques for the alignment of toric IOLs. In conclusion, image-guided systems seem to be an accurate and reliable technology with measurements of high repeatability and reproducibility regarding the keratometry and IOL power calculation, but not yet interchangeable with the current established and validated keratometric devices. However, they are superior over the conventional manual ink-marking techniques for toric IOL alignment.

    Reference
    1 Velasco-Barona C, Cervantes-Coste G, Mendoza-Schuster E, Corredor-Ortega C, Casillas-Chavarín NL, Silva-Moreno A, Garza-León M, Gonzalez-Salinas R. Comparison of biometric measurements obtained by the Verion Image-Guided System versus the auto-refracto-keratometer. Int Ophthalmol 2018;38(3):951-957.
    2 Asena L, Güngör SG, Akman A. Comparison of keratometric measurements obtained by the Verion Image Guided System with optical biometry and auto-keratorefractometer. Int Ophthalmol 2017;37(2):391-399.
    3 Ferrer-Blasco T, Montés-Micó R, Peixoto-de-Matos SC, González-Méijome JM, Cerviño A. Prevalence of corneal astigmatism before cataract surgery. J Cataract Refract Surg 2009;35(1):70-75.
    4 Chen W, Zuo C, Chen C, Su J, Luo L, Congdon N, Liu Y. Prevalence of corneal astigmatism before cataract surgery in Chinese patients. J Cataract Refract Surg 2013;39(2):188-192.
    5 Hoffmann PC, Hütz WW. Analysis of biometry and prevalence data for corneal astigmatism in 23,239 eyes. J Cataract Refract Surg 2010;36(9): 1479-1485.
    6 Yuan X, Song H, Peng G, Hua X, Tang X. Prevalence of corneal astigmatism in patients before cataract surgery in Northern China. J Ophthalmol 2014;2014:536412.
    7 Mohammad-Rabei H, Mohammad-Rabei E, Espandar G, Javadi MA, Jafarinasab MR, Hashemian SJ, Feizi S. Three methods for correction of astigmatism during phacoemulsification. J Ophthalmic Vis Res 2016;11(2):162-167.
    8 Day AC, Stevens JD. Stability of keratometric astigmatism after non-penetrating femtosecond laser intrastromal astigmatic keratotomy performed during laser cataract surgery. J Refract Surg 2016;32(3): 152-155.
    9 Khokhar S, Lohiya P, Murugiesan V, Panda A. Corneal astigmatism correction with opposite clear corneal incisions or single clear corneal incision: comparative analysis. J Cataract Refract Surg 2006;32(9): 1432-1437.
    10 Visser N, Beckers HJ, Bauer NJ, Gast ST, Zijlmans BL, Berenschot TT, Webers CA, Nuijts RM. Toric vs aspherical control intraocular lenses in patients with cataract and corneal astigmatism: a randomized clinical trial. JAMA Ophthalmol 2014;132(12):1462-1468.
    11 Riederle F, Buchwald HJ, Preissinger C, Lang GK. Refractive aspects of modern cataract surgery. Klin Monatsbl Augenheilkd 2006;223(12): 943-951.
    12 Venter J, Pelouskova M. Outcomes and complications of a multifocal toric intraocular lens with a surface-embedded near section. J Cataract Refract Surg 2013;39(6):859-866.
    13 Ferreira TB, Marques EF, Rodrigues A, Montés-Micó R. Visual and optical outcomes of a diffractive multifocal toric intraocular lens. J Cataract Refract Surg 2013;39(7):1029-1035.
    14 Visser N, Nuijts RM, de Vries NE, Bauer NJ. Visual outcomes and patient satisfaction after cataract surgery with toric multifocal intraocular lens implantation. J Cataract Refract Surg 2011;37(11):2034-2042.
    15 Crema AS, Walsh A, Ventura BV, Santhiago MR. Visual outcomes of eyes implanted with a toric multifocal intraocular lens. J Refract Surg 2014;30(7):486-491.
    16 Brick DC. Risk management lessons from a review of 168 cataract surgery claims. Surv Ophthalmol 1999;43(4):356-360.
    17 Viestenz A, Seitz B, Langenbucher A. Evaluating the eye’s rotational stability during standard photography: effect on determining the axial orientation of toric intraocular lenses. J Cataract Refract Surg 2005;31(3): 557-561.
    18 Felipe A, Artigas JM, Diez-Ajenjo A, Garcia-Domene C, Alcocer P. Residual astigmatism produced by toric intraocular lens rotation. J Cataract Refract Surg 2011;37(10):1895-1901.
    19 Hill W, Potvin R. Monte Carlo simulation of expected outcomes with the AcrySof® toric intraocular lens. BMC Ophthalmol 2008;8:22.
    20 Ma JJ, Tseng SS. Simple method for accurate alignment in toric phakic and aphakic intraocular lens implantation. J Cataract Refract Surg 2008;34(10):1631-1636.
    21 Osher RH. Iris fingerprinting: new method for improving accuracy in toric lens orientation. J Cataract Refract Surg 2010;36(2):351-352.
    22 Hura AS, Osher RH. Comparing the Zeiss Callisto Eye and the Alcon Verion Image Guided System Toric Lens Alignment Technologies. J Refract Surg 2017;33(7):482-487.
    23 Solomon JD, Ladas J. Toric outcomes: computer-assisted registration versus intraoperative aberrometry. J Cataract Refract Surg 2017;43(4): 498-504.
    24 Montes de Oca I, Kim EJ, Wang L, Weikert MP, Khandelwal SS, Al-Mohtaseb Z, Koch DD. Accuracy of toric intraocular lens axis alignment using a 3-dimensional computer-guided visualization system. J Cataract Refract Surg 2016;42(4):550-555.
    25 Raucau M, El Chehab H, Agard E, Lagenaite C, Dot C. Toric lens implantation in cataract surgery: automated versus manual horizontal axis marking, analysis of 50 cases. J Fr Ophtalmol 2018;41(1):e1-e9.
    26 Webers VSC, Bauer NJC, Visser N, Berendschot TTJM, van den Biggelaar FJHM, Nuijts RMMA. Image-guided system versus manual marking for toric intraocular lens alignment in cataract surgery. J Cataract Refract Surg 2017;43(6):781-788.
    27 Webers VSC, de Visser N, Bauer NJC, Berendschot TTJM, van de Biggelaar-Bovers FJHM, Nuijts RMMA. Evaluation of a novel eye-tracking navigation system in the alignment of toric IOLs in cataract surgery: a randomised control trial. Acta Ophthalmol 2017;95:33-34.
    28 Mayer WJ, Kreutzer T, Dirisamer M, Kern C, Kortuem K, Vounotrypidis E, Priglinger S, Kook D. Comparison of visual outcomes, alignment accuracy, and surgical time between 2 methods of corneal marking for toric intraocular lens implantation. J Cataract Refract Surg 2017;43(10):1281-1286.
    29 Thomas BC, Müller A, Auffarth GU, Holzer MP. Duration of examination and patient comfort with a new biometric device, in comparison to three established devices. Klin Monbl Augenheilkd 2016;233(8):933-937.
    30 Mueller A, Thomas BC, Auffarth GU, Holzer MP. Comparison of a new image-guided system versus partial coherence interferometry, Scheimpflug imaging, and optical low-coherence reflectometry devices: Keratometry and repeatability. J Cataract Refract Surg 2016;42(5): 672-678.
    31 Thomas BC, Mueller A, Auffarth GU, Holzer MP. Influence on intraocular lens power calculation of corneal radii measurement using an image-guided system. J Cataract Refract Surg 2016; 42(11):1588-1594.
    32 Visser N, Berendschot TT, Verbakel F, de Brabander J, Nuijts RM. Comparability and repeatability of corneal astigmatism measurements using different measurement technologies. J Cataract Refract Surg 2012;38(10):1764-1770.
    33 Ruiz-Belda C, Rodrigo F, Piñero DP. Validation of keratometric measurements obtained with an intraoperative image-guided system: intra-session repeatability and interchangeability with an optical biometer. Clin Exp Optom 2018;101(2):200-205.
    34 Lin HY, Fang YT, Chuang YJ, Karlin JN, Chen HY, Lin SY, Lin PJ, Chen M. A comparison of three different corneal marking methods used to determine cyclotorsion in the horizontal meridian. Clin Ophthalmol 2017;11:311-315.
    35 Lin HY, Chen HY, Fam HB, Chuang YJ, Yeoh R, Lin PJ. Comparison of corneal power obtained from VERION image-guided surgery system and four other devices. Clin Ophthalmol 2017;11:1291-1299.
    36 Lauschke JL, Lawless M, Sutton G, Roberts TV, Hodge C. Assessment of corneal curvature using verion optical imaging system: a comparative study. Clin Exp Ophthalmol 2016;44(5):369-376.
    37 Schultz M, Oberheide U, Kermani O. Comparability of an image-guided system with other instruments in measuring corneal keratometry and astigmatism. J Cataract Refract Surg 2016;42(6):904-912.
    38 Davison JA, Potvin R. Refractive cylinder outcomes after calculating toric intraocular lens cylinder power using total corneal refractive power. Clin Ophthalmol 2015;9:1511-1517.
    39 Zhao F, Li L, Zhou W, Shi D, Fan Y, Ma L. Correlative factors’ analysis of postural-related ocular cyclotorsion with image-guided system. Jpn J Ophthalmol 2018;62(2):237-242.
    40 Nemeth G, Szalai E, Hassan Z, Lipecz A, Berta A, Modis L Jr. Repeatability data and agreement of keratometry with the VERION system compared to the IOLMaster. J Refract Surg 2015;31(5):333-337.
    41 Elhofi AH, Helaly HA. Comparison between digital and manual marking for toric intraocular lenses: a randomized trial. Medicine (Baltimore) 2015;94(38):e1618.
    42 Verion Reference Unit. Alcon Laboratories. Fort Worth, Texas. Available at: http://crstoday.com/pdfs/0614_supp2.pd. Accessed on: Aug. 24, 2018.
    43 CALLISTO Eye, Computer assisted cataract surgery, ZEISS. Available at: https://www.zeiss.com/meditec/int/products/ophthalmology-optometry/cataract/visualization/computer-assisted-cataract-surgery/callisto-eye.html#highlights. Accessed on: Jul. 12, 2018.
    44 Shirayama M, Wang L, Weikert MP, Koch DD. Comparison of corneal powers obtained from 4 different devices. Am J Ophthalmol 2009;148(4): 528-535.e1.
    45 The Aladdin Biometer HW3.0, Product Description. Available at: http://www.topcon-medical.de/files/EU_Downloads/Products/Aladdin/ALADDIN_User_Manual_en.pdf. Accessed on: Aug. 24, 2018.
    46 Ruhswurm I, Scholz U, Zehetmayer M, Hanselmayer G, Vass C, Skorpik C. Astigmatism correction with a foldable toric intraocular lens in cataract patients. J Cataract Refract Surg 2000;26(7):1022-1027.
    47 Potvin R, Kramer BA, Hardten DR, Berdahl JP. Toric intraocular lens orientation and residual refractive astigmatism: an analysis. Clin Ophthalmol 2016;10:1829-1836.
    48 Miyake T, Kamiya K, Amano R, Iida Y, Tsunehiro S, Shimizu K. Long-term clinical outcomes of toric intraocular lens implantation in cataract cases with preexisting astigmatism. J Cataract Refract Surg 2014;40(10):1654-1660.
    49 Lane SS. The AcrySof toric IOL’s FDA trial results; a look at the clinical data. Cataract & Refractive Surgery Today, May 2006, pages 66-68. Available at: http://bmctoday.net/crstoday/pdfs/CRST0506_11.pdf. Accessed on: Aug. 24, 2018.
    50 Shah GD, Praveen MR, Vasavada AR, Vasavada VA, Rampal G, Shastry LR. Rotational stability of a toric intraocular lens: influence of axial length and alignment in the capsular bag. J Cataract Refract Surg 2012;38(1):54-59.
    51 Patel CK, Ormonde S, Rosen PH, Bron AJ. Postoperative intraocular lens rotation: a randomized comparison of plate and loop haptic implants. Ophthalmology 1999;106(11):2190-2195.
    52 Prinz A, Neumayer T, Buehl W, Vock L, Menapace R, Findl O, Georgopoulos M. Rotational stability and posterior capsule opacification of a plate-haptic and an open-loop-haptic intraocular lens. J Cataract Refract Surg 2011;37(2):251-257.
    53 McAlinden C, Khadka J, Pesudovs K. Statistical methods for conducting agreement (comparison of clinical tests) and precision (repeatability or reproducibility) studies in optometry and ophthalmology. Ophthalmic Physiol Opt 2011;31(4):330-338.
    54 Bland JM, Altman DG. Measurement error. BMJ 1996;313(7059):744.
    55 Browne AW, Osher RH. Optimizing precision in toric lens selection by combining keratometry techniques. J Refract Surg 2014;30(1):67-72.
    56 Koch DD, Ali SF, Weikert MP, Shirayama M, Jenkins R, Wang L. Contribution of posterior corneal astigmatism to total corneal astigmatism. J Cataract Refract Surg 2012;38(12):2080-2087.
    57 Koch DD, Jenkins RB, Weikert MP, Yeu E, Wang L. Correcting astigmatism with toric intraocular lenses: effect of posterior corneal astigmatism. J Cataract Refract Surg 2013;39(12):1803-1809.
    58 Koch DD. The enigmatic cornea and intraocular lens calculations: the LXXIII Edward Jackson Memorial Lecture. Am J Ophthalmol 2016;171:xv-xxx.
    59 Abulafia A, Barrett GD, Kleinmann G, Ofir S, Levy A, Marcovich AL, Michaeli A, Koch DD, Wang L, Assia EI. Prediction of refractive outcomes with toric intraocular lens implantation. J Cataract Refract Surg 2015; 41(5):936-944.
    60 Abulafia A, Hill WE, Franchina M, Barrett GD. Comparison of methods to predict residual astigmatism after intraocular lens implantation. J Refract Surg 2015;31(10):699-707.
    61 Zhang L, Sy ME, Mai H, Yu F, Hamilton DR. Effect of posterior corneal astigmatism on refractive outcomes after toric intraocular lens implantation. J Cataract Refract Surg 2015;41(1):84-89.
    62 Eom Y, Rhim JW, Kang SY, Kim SW, Song JS, Kim HM. Toric intraocular lens calculations using ratio of anterior to posterior corneal cylinder power. Am J Ophthalmol 2015;160(4):717-724.e2.
    63 Labiris G, Ntonti P, Patsiamanidi M, Sideroudi H, Georgantzoglou K, Kozobolis VP. Evaluation of activities of daily living following pseudophakic presbyopic correction. Eye Vis (Lond) 2017;4:2.
    64 Labiris G, Giarmoukakis A, Patsiamanidi M, Papadopoulos Z, Kozobolis VP. Mini-monovision versus multifocal intraocular lens implantation. J Cataract Refract Surg 2015;41(1):53-57.
    65 Labiris G, Patsiamanidi M, Giarmoukakis A, Kozobolis VP. Patient satisfaction and spectacle independence with the iSert multifocal lens. Eur J Ophthalmol 2015;25(2):e1-e2.
    Cited by
    Comments
    Comments
    分享到微博
    Submit
Get Citation

Eirini-Kanella Panagiotopoulou, Panagiota Ntonti, Maria Gkika,/et al.Image-guided lens extraction surgery: a systematic review. Int J Ophthalmol, 2019,12(1):135-151

Copy
Share
Article Metrics
  • Abstract:1679
  • PDF: 697
  • HTML: 310
  • Cited by: 0
Publication History
  • Received:August 26,2018
  • Revised:October 09,2018
  • Online: January 03,2019