Effect of biometric characteristics on biomechanical properties of the cornea in cataract patient
Author:
Corresponding Author:

Xue-Fei Song. Department of Ophthalmology, Saarland University Medical Center, Kirrberger Str 100, Homburg Saar 66424, Germany. 89215667@qq.com

Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    AIM: To determine the impact of biometric characteristics on the biomechanical properties of the human cornea using the ocular response analyzer (ORA) and standard comprehensive ophthalmic examinations before and after standard phacoemulsification. METHODS: This study comprised 54 eyes with cataract with significant lens opacification in stages I or II that underwent phacoemulsification (2.8 mm incision). Corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-correlated intraocular pressure (IOPg), and corneal-compensated intraocular pressure (IOPcc) were measured by ORA preoperatively and at 1mo postoperatively. Biometric characteristics were derived from corneal topography [TMS-5, anterior equivalent (EQTMS) and cylindric (CYLTMS) power], corneal tomography [Casia, anterior and posterior equivalent (EQaCASIC, EQpCASIA) and cylindric (CYLaCASIA, CYLpCASIA) power], keratometry [IOLMaster, anterior equivalent (EQIOL) and cylindric (CYLIOL) power] and autorefractor [anterior equivalent (EQAR)]. Results from ORA were analyzed and correlated with those from all other examinations taken at the same time point. RESULTS: Preoperatively, CH correlated with EQpCASIA and CYLpCASIA only (P=0.001, P=0.002). Postoperatively, IOPg and IOPcc correlated with all equivalent powers (EQTMS, EQIOL, EQAR, EQaCASIA and EQpCASIA) (P=0.001, P=0.007, P=0.001, P=0.015, P=0.03 for IOPg and P<0.001, P=0.003, P<0.001, P=0.009, P=0.014 for IOPcc). CH correlated postoperatively with EQaCASIA and EQpCASIC only (P=0.021, P=0.022). CONCLUSION: Biometric characteristics may significantly affect biomechanical properties of the cornea in terms of CH, IOPcc and IOPg before, but even more after cataract surgery.

    Reference
    Related
    Cited by
Get Citation

Xue-Fei Song, Achim Langenbucher, Zisis Gatzioufas, et al. Effect of biometric characteristics on biomechanical properties of the cornea in cataract patient. Int J Ophthalmol, 2016,9(6):854-857

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
Publication History
  • Received:January 19,2015
  • Revised:March 11,2015
  • Adopted:
  • Online: June 16,2016
  • Published: