[关键词]
[摘要]
目的:比较两种散光矫正型人工晶状体植入术后1mo旋转稳定性及临床效果。 方法:回顾性病例对照研究。选取2023-10/2026-3于我院眼科行白内障超声乳化摘除联合TIOL植入术的白内障患者55例(66眼),依据植入TIOL类型分为改良型L型襻组(31眼)和平板襻组(35眼)。术后1d评估裸眼远视力(UDVA)及眼压(IOP);术后1mo评估最佳矫正远视力(BCDVA)、残余散光(RAS)及TIOL旋转角度。分析TIOL旋转度与眼轴长度(AL)、前房深度(ACD)、角膜缘白到白距离(WTW)、术前总角膜散光(TK)、平坦轴角膜曲率(K1)、晶状体厚度(LT)、眼前节长度(ASL)及术后1d IOP波动绝对值的相关性。 结果:共纳入66眼(改良型L型襻组31眼,平板襻组35眼)。两组在性别、年龄、术前UDVA、IOP及各项眼部解剖参数(AL、ACD、WTW、TK、K1、ASL、LT)方面均无差异(均P>0.05)。术后1mo,平板襻组TIOL旋转度显著小于改良型L型襻组(旋转度 2.04(0.37,4.44) vs 3.38(1.75,6.18),Wald χ²=5.194,P=0.023);两组术后1 d UDVA提升值差异无统计学意义(P=0.445),平板襻组术后1 d IOP波动绝对值较小(P=0.021);两组术后1 mo BCDVA及残余散光差异均无统计学意义(均P>0.05)。WTW与术后1 mo TIOL旋转度呈边界性正向关联(β=1.695,P=0.0497),ASL和AL呈正向关联趋势,但均未达到统计学意义,其余眼部生物学参数及术后1 d IOP波动绝对值均未见显著关联;两组均未发生严重术中或术后并发症,仅改良型L型襻组术后1mo1眼并发PCO。 结论:相较于改良L 型襻TIOL,平板襻TIOL 在术后 1 个mo具有更好的旋转稳定性。但两组早期视力及残余散光结果无显著差异。校正TIOL类型后,WTW与术后早期TIOL旋转度呈正向关联,其临床意义仍需进一步验证。 关键词:白内障;角膜散光;散光矫正型人工晶状体;旋转稳定性;视觉质量
[Key word]
[Abstract]
Objective: To compare the early rotational stability and clinical outcomes of two toric intraocular lenses (TIOLs) with different haptic designs at 1 month after implantation. Methods: This retrospective case-control study included 55 patients (66 eyes) with cataract who underwent phacoemulsification combined with TIOL implantation between October 2023 and March 2026. According to the implanted TIOL type, 31 eyes were assigned to the modified L-shaped haptic group and 35 eyes to the plate-haptic group. Uncorrected distance visual acuity (UDVA) and intraocular pressure (IOP) were evaluated on postoperative day 1. Best-corrected distance visual acuity (BCDVA), residual astigmatism (RAS), and TIOL rotation were assessed at postoperative month 1. Generalized estimating equations (GEE) were used to account for correlations between fellow eyes from the same patient. Associations between TIOL rotation and axial length (AL), anterior chamber depth (ACD), white-to-white distance (WTW), preoperative total keratometric astigmatism (TK), flat keratometry (K1), lens thickness (LT),anterior segment length (ASL), and the absolute change in IOP on postoperative day 1 were also evaluated. Results: A total of 66 eyes were included, with 35 eyes in the plate-haptic group and 31 eyes in the modified L-shaped haptic group. No significant between-group differences were observed in sex, age, preoperative UDVA, IOP, or ocular biometric parameters (all P > 0.05). At postoperative month 1, TIOL rotation was significantly smaller in the plate-haptic group than in the modified L-shaped haptic group [2.04 (0.37, 4.44) degrees vs. 3.38 (1.75, 6.18) degrees; Wald chi-square = 5.194, P = 0.023]. Improvement in UDVA on postoperative day 1 did not differ significantly between the groups (P = 0.445), whereas the absolute change in IOP was significantly smaller in the plate-haptic group (P = 0.021). No significant between-group differences were observed in BCDVA or residual astigmatism at postoperative month 1 (both P > 0.05). After adjustment for TIOL type, WTW showed a borderline positive association with TIOL rotation (beta = 1.695, P = 0.0497), ASL and AL showed nonsignificant positive trends, whereas the other ocular biometric parameters and the absolute change in IOP on postoperative day 1 were not significantly associated with TIOL rotation. No serious intraoperative or postoperative complications occurred in either group. One eye in the modified L-shaped haptic group developed posterior capsule opacification at postoperative month 1. Conclusion: Compared with the modified L-shaped haptic TIOL, the plate-haptic TIOL demonstrated better rotational stability at 1 month postoperatively, while no statistically significant differences were observed in early visual outcomes or residual astigmatism between the two groups. After adjustment for TIOL type, white-to-white distance (WTW) was positively associated with early postoperative TIOL rotation, although the clinical significance of this association requires further validation. Keywords: Cataract; Corneal astigmatism; Toric intraocular lens; Rotational stability; Visual outcomes
[中图分类号]
[基金项目]
徐州市卫生健康委科技项目