[关键词]
[摘要]
目的:研究发光二极管衍生的蓝光短时间暴露对人眼表的影响。
方法:本研究是一项前瞻性、非随机、比较性临床研究。收集2026年2月至2026年5月就诊于我院体检科的健康成年志愿者,完善眼表检查后参加了本研究。对照近距离暴露于发光二极管衍生的蓝光前后眼表疾病指数(OSDI)问卷评分、泪液分泌量、非接触式泪膜破裂时间(NIBUT)及角膜荧光素钠染色的变化。同时使用ELISA测量泪膜中的氧化应激标记物,包括泪膜中的己酰赖氨酸(HEL)及4-羟基-2-壬醛(4-HNE)。所有测量均在基线状态,使用智能手机1、4 h后进行。
结果:本研究纳入健康成年志愿者30名,年龄21-35岁(因中青年群体是使用智能手机时长最长的人群),平均年龄27.70±4.04岁,男女比例1∶1。参与者4 h时的OSDI问卷评分与基线和1 h时相比显著增加(均P<0.05)。参与者4 h时的NIBUT与基线和1 h时相比显著降低(均P<0.05)。参与者4 h时的HEL浓度与基线、1 h时比较显著增加(均P<0.05)。参与者不同时间的泪液分泌量、角膜荧光染色、4-HNE均无差异(均P>0.05)。
结论:尽量降低凝视时眨眼间隔时间延长导致泪液过度蒸发及近距离用眼调节集合负荷的情况下,使用智能手机近距离暴露于发光二极管衍生的蓝光不仅会加重主观眼部症状,使眼表的泪膜不稳定及泪液的氧化应激指数增高,最终可诱发眼表氧化应激升高,存在角膜氧化损伤、眼表炎症及干眼的潜在风险。
[Key word]
[Abstract]
AIM: To investigate the effects of short-term exposure to light emitting diode(LED)-derived blue light on the human ocular surface.
METHODS: This was a prospective, non-randomized, comparative clinical study. Healthy adult volunteers visiting the Physical Examination Department of our hospital between February 2026 and May 2026 were enrolled in this study after completing ocular surface examinations. Ocular surface disease index(OSDI), tear secretion volume, non-invasive keratograph break-up time(NIBUT), and corneal sodium fluorescein staining were measured before and after close-range exposure to LED-derived blue light. The tear film concentrations of oxidative stress markers, hexanoyl-lysine(HEL)and 4-hydroxy-2-nonenal(4-HNE), were quantified by enzyme-linked immunosorbent assay(ELISA). All measurements were performed at baseline, and at 1 h and 4 h after blue light exposure via smartphone.
RESULTS: Thirty healthy adult volunteers aged 21-35 y were enrolled(young and middle-aged people have the longest smartphone usage duration), with a mean age of 27.70±4.04 y and a male-to-female ratio of 1∶1.The OSDI scores at 4 h were significantly elevated compared with baseline and 1 h(all P<0.05). NIBUT at 4 h decreased significantly relative to baseline and 1 h(all P<0.05). HEL concentrations at 4 h were significantly higher than those at baseline and 1 h(all P<0.05). There were no significant differences in tear secretion volume, corneal fluorescein staining and 4-HNE levels across all time points(all P>0.05).
CONCLUSION: While minimizing excessive tear evaporation caused by prolonged inter-blink intervals during gazing and the accommodative-convergence load associated with near work, close-range exposure to blue light emitted by LEDs from smartphones not only exacerbates subjective symptom but also destabilizes the tear film and elevates oxidative stress levels in tears. This may increase ocular surface oxidative stress, thereby contributing to potential risks of corneal oxidative damage, ocular surface inflammation, and dry eye.
[中图分类号]
[基金项目]
吉林省自然科学基金项目(No.YDZJ202401111ZYTS)