[关键词]
[摘要]
目的:研究基于超声生物显微镜(UBM)测量的睫状沟直径(STS)等数据选择有晶状体眼后房型人工晶状体(ICL)尺寸对术后拱高的安全性及有效性的影响,同时探讨影响拱高的相关因素。
方法:前瞻性病例观察研究。选取福州眼科医院2022-01/12收治的行ICL植入术并规律复查6 mo的患者,纳入进行ICL尺寸优化的95例188眼屈光不正患者为优化组; 未进行ICL尺寸优化的90例174眼屈光不正患者为普通组。分别于术后1 d,1 wk,1、3、6 mo进行随访,收集裸眼视力(UCVA)、最佳矫正视力(BCVA)、屈光情况、眼压(IOP)、角膜情况、前房深度(ACD)、房角开放度、拱高、角膜内皮细胞计数等资料。
结果:两组术后等效球镜、UCVA、BCVA组间比较无差异(均P>0.05)。优化组和普通组患者术后6 mo的视力安全指数分别为1.21±0.24、1.19±0.21,视力疗效指数分别为1.18±0.22、1.07±0.26。两组患者术后6 mo拱高分别为407.77±159.31、467.16±250.07 μm,优化组92.0%眼术后拱高达到理想状态,普通组74.1%眼术后拱高达到理想状态; 两组患者术后拱高随时间有轻微下降趋势,组间比较无差异(F组间=3.478,P组间=0.063)。普通组术后存在6眼ICL置换、2眼因房角关闭诱发急性闭角型青光眼而导致ICL取出的病例。
结论:基于UBM测量的STS等数据选择ICL尺寸并设计植入方向,具有良好的安全性、有效性和拱高可预测性。
[Key word]
[Abstract]
AIM:To investigate the safety and efficacy of selecting implantable collamer lens(ICL)size for postoperative vaults using sulcus to sulcus(STS)and other data measured by ultrasound biomicroscopy(UBM), and to explore the relevant factors affecting vaults.
METHODS: Prospective case observational study. A total of 95 patients(188 eyes)with ametropia who underwent ICL size optimization and 90 patients(174 eyes)without ICL size optimization, from January to December 2022 and underwent regular follow-up for 6 mo were selected. Patients were divided into an optimized group and a standard group based on whether ICL size optimization was performed. The patients were followed up at 1 d, 1 wk, 1, 3, and 6 mo, and uncorrected visual acuity(UCVA), best corrected visual acuity(BCVA), refraction state, intraocular pressure(IOP), corneal status, anterior chamber depth(ACD), angle opening, vaults and corneal endothelial cell count were collected.
RESULTS: No significant difference in spherical equivalent, UCVA and BCVA was found between the two groups(all P >0.05). The safety index was 1.21±0.24 and 1.19±0.21 at 6 mo for the two groups, respectively, while the efficacy index were 1.18±0.22 and 1.07±0.26. The vaults at 6 mo for the two groups was 407.77±159.31 and 467.16±250.07 μm, respectively. In the optimization group, 92.0% of eyes achieved the desired vaults postoperatively, while 74.1% of eyes in the standard group reached the desired vaults. Both groups exhibited a slight downward trend in vaults over time, with no significant differences between the two groups(F=3.478, P=0.063). However, the standard group experienced 6 eyes of ICL replacement and 2 eyes of ICL removal due to acute angle-closure glaucoma induced by angle closure.
CONCLUSION: Selecting the ICL size and determining the implantation orientation based on sulcus to sulcus(STS)and other data measured by UBM provides good safety, efficacy, and predictability for postoperative vaults.
[中图分类号]
[基金项目]