目的:观察术中三面镜检查引导手术治疗睫状体分离的临床效果。
方法:手术通过术前UBM联合三面镜检查,术中三面镜再次定位睫状体断离口的位置和范围,引导手术。本组16例16眼患者均采用该方法,行睫状体缝合复位术。
结果:所有患者术后观察3~6mo,最佳矫正视力0.1~0.8; 眼压恢复至11~21mmHg; 前房、瞳孔、眼底改变基本恢复正常。
结论:本组16例患者采用术中三面镜定位引导手术治疗挫伤性睫状体分离,取得效果确切; 通过临床治疗结果,说明该方法安全、有效。
[Key word]
[Abstract]
AIM: To observe clinical effect of cyclodialysis suture surgery guided by intraoperative three-mirror lens.
METHODS: Ultrasound biomicroscopy(UBM)and three-mirror lens were taken before operations. Three-mirror lens was used to confirm the position and range of the cyclodialysis and to guide the operations. All the 16 patients(16 eyes)received this operation.
RESULTS: All patients were observed for 3-6mo. The best corrected visual acuity was 0.1 to 0.8; intraocular pressure returned to 11-21mmHg; anterior chamber, pupil, fundus changes returned to normal.
CONCLUSION: It is effective and safe to treat cyclodialysis with suture guided by intraoperative three-mirror lens.